Division KELLER
Please choose your language:

Furnace pyrometers

Application report on the non-contact temperature measurement in furnaces

Application report furnace applications

In the manufacture of ceramic products, the temperature curve in the kiln has a significant influence on the reject rate and fuel consumption. For optimal kiln control, accurate measuring devices are therefore required, which ideally record the material temperature directly.

Pyrometers have proved their worth for measuring the temperature. They measure the infrared radiation of the objects and calculate the temperature from it. The measurement is carried out optically and thus wear-free from a safe distance. The measurement takes place in a few milliseconds. Pyrometers can therefore be used to maintain the optimum firing curve much more precisely and thus minimize fuel consumption.

Features

  • application solutions for all relevant measuring points
  • compact design with integrated temperature display
  • short measuring time and thus precise control of the furnace temperature
directly to the application solutions
Application report Furnace
en
INDICE 6 Login
© 2001-2024 – Internetagentur – Wrocklage Werbewerkstatt