Pyrometer CellaCombustion PT 118
Article description
The CellaCombustion PT 118 measures at a special wavelength at which the chemical components of the hot combustion gas have a high optical density. These devices are used in large combustion plants such as thermal waste disposal plants and coal-fired power plants.
Special features:
Measuring range 500 to 2,500 °C
focusable lenses for exact adjustment of the measuring distance
broadband anti-reflective precision lens
LED display
standard feature: USB interface
Pyrometer CellaCombustion PT 118
Properties
Version
Measuring range
500 - 2500 °C
500 - 2500 °C
Focus distance
0,8 m - ∞
0,8 m - ∞
Sighting option
Through-the-lens-sighting
Through-the-lens-sighting
Your selection will affect other settings
Version
AF 1
Sighting option
Through-the-lens-sighting
You can request this article from us
Quantity:
Request article
Version
CellaCombustion PT 118 AF 1
Measuring range
500 - 2500 °C
Focus distance
0,8 m - ∞
Shape of the measuring field
round
Distance ratio
70 : 1
Objective
PZ 15.03
Measuring principle
one-colour
Sighting option
Through-the-lens-sighting
Technical Data
Downloads
Measuring field calculator
Emissivity calculator
Application request
Pyrometer CellaCombustion PT 118
Technical Data
Measurement parameters
Measuring range
500 - 2500 °C
Sensor
Thermopile
Spectral range
CO range
Response time t98
≤ 100 ms
Measurement uncertainty
0.75 % of temp. reading [°C], min. 3 K
Repeatability
2 K
Temperature coefficient
0.04 %/K
Resolution interface
0.1 K
Resolution display
1 K
Optical variants
Lenses
Standard-Objektiv PZ 15.03: Fokussierung 0,8 m - ∞
Electrical parameters
Interface
USB
Power supply
Rechargeable battery pack
Battery life: approx. 15 hours (based on continuous operation at Ta=23 °C)
Features
Sighting option
Through-the-lens-sighting
Display
4-digit LED display red, digit-height 8 mm
Status display
2 x LED external
3 x LED internal
Control elements
3 buttons
General parameters
Ambient temperature
0 - 50 °C
Storage temperature
-20 - +60 °C
Permissible humidity
95 % r.H. max. (non-condensing)
Dimension
Ø 65 mm x 197 mm (plus lens length)
Housing
Aluminium
Protection class
IP 40 acc. to DIN 40050
Weight
approx. 1.1 kg
Adjustable parameters
Parameters
Emissivity
Locations of the emissivity tables
Transmittance
Compensation of the reflected ambient radiation
Smoothing filter
Operation mode and hold time of the data memory
Parameters of the ATD function
Linearization function
Status display of the LEDs
Temperature unit °C/°F
Automatic shutdown
Functions
ATD-(Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Scope of delivery
Scope of delivery
Pyrometer CellaCombustion PT
Protective and carrying case
Charger
USB cable VK 11/D (1.8 m)
Software CellaView
Manual (short)
Software
Software
CellaView
Pyrometer CellaCombustion PT 118
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset on the pyrometer and the ambient temperature (necessary for some types).
Calculation of the measured value
From the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for types), the measured value calculated by the pyrometer is displayed.
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Measured value of the pyrometer
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Measured value of the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaCombustion PT 118
Downloads
Brochure CellaPort PT
Brochure CellaView
Application report CellaCombustion
Manual CellaPort PT 11x 12x 13
Quick guide CellaPort PT 11x 12x 13x
UKCA Declaration from Conformity PT1xx
EAC Deklaration PK-PA-PT
X
Pyrometer CellaCombustion PT 118
Accessories
Wir haben leider kein passendes Zubehör gefunden.
Pyrometer CellaCombustion PT 118
IO-Link IODD
Pyrometer CellaCombustion PT 118
IO-Link Manufacturer explanation
Pyrometer CellaCombustion PT 118
Measuring field calculator
Pyrometer
PT 118 AF 1
(0,8 m - ∞)
PT 118 AF 1
(0,8 m - ∞)
Focus distance
mm
Graphic length
mm
Calculate
Print
Measuring distance (mm)
0
64
128
192
256
320
384
448
512
576
640
704
768
11.43 mm
Measuring distance
Measuring field diameter
0.00 mm
24.00 mm
32.00 mm
23.50 mm
64.00 mm
22.99 mm
96.00 mm
22.49 mm
128.00 mm
21.99 mm
160.00 mm
21.49 mm
192.00 mm
20.98 mm
224.00 mm
20.48 mm
256.00 mm
19.98 mm
288.00 mm
19.47 mm
320.00 mm
18.97 mm
352.00 mm
18.47 mm
384.00 mm
17.97 mm
416.00 mm
17.46 mm
448.00 mm
16.96 mm
480.00 mm
16.46 mm
512.00 mm
15.95 mm
544.00 mm
15.45 mm
576.00 mm
14.95 mm
608.00 mm
14.45 mm
640.00 mm
13.94 mm
672.00 mm
13.44 mm
704.00 mm
12.94 mm
736.00 mm
12.43 mm
768.00 mm
11.93 mm
800.00 mm
11.43 mm
Request
Shipping costs for
Andorra
United Arab Emirates
Afghanistan
Antigua and Barbuda
Anguilla
Albania
Armenia
Netherlands Antilles
Angola
Antarctica
Argentina
American Samoa
Austria
Australia
Aruba
Azerbaijan
Bosnia and Herzegovina
Barbados
Bangladesh
Belgium
Burkina Faso
Bulgaria
Bahrain
Burundi
Benin
Bermuda
Brunei Darussalam
Bolivia
Brazil
Bahamas
Bhutan
Bouvet Island
Botswana
Belarus
Belize
Canada
Cocos (Keeling) Islands
Congo, the Democratic Republic of the
Central African Republic
Congo
Switzerland
Cote D'Ivoire
Cook Islands
Chile
Cameroon
China
Colombia
Costa Rica
Serbia and Montenegro
Cuba
Cape Verde
Christmas Island
Cyprus
Czech Republic
Germany
Djibouti
Denmark
Dominica
Dominican Republic
Algeria
Ecuador
Estonia
Egypt
Western Sahara
Eritrea
Spain
Ethiopia
Finland
Fiji
Falkland Islands (Malvinas)
Micronesia, Federated States of
Faroe Islands
France
Gabon
United Kingdom
Grenada
Georgia
French Guiana
Ghana
Gibraltar
Greenland
Gambia
Guinea
Guadeloupe
Equatorial Guinea
Greece
South Georgia and the South Sandwich Islands
Guatemala
Guam
Guinea-Bissau
Guyana
Hong Kong
Heard Island and Mcdonald Islands
Honduras
Croatia
Haiti
Hungary
Indonesia
Ireland
Israel
India
British Indian Ocean Territory
Iraq
Iran, Islamic Republic of
Iceland
Italy
Jamaica
Jordan
Japan
Kenya
Kyrgyzstan
Cambodia
Kiribati
Comoros
Saint Kitts and Nevis
Korea, Democratic People's Republic of
Korea, Republic of
Kuwait
Cayman Islands
Kazakhstan
Lao People's Democratic Republic
Lebanon
Saint Lucia
Liechtenstein
Sri Lanka
Liberia
Lesotho
Lithuania
Luxembourg
Latvia
Libyan Arab Jamahiriya
Morocco
Monaco
Moldova, Republic of
Madagascar
Marshall Islands
Macedonia, the Former Yugoslav Republic of
Mali
Myanmar
Mongolia
Macao
Northern Mariana Islands
Martinique
Mauritania
Montserrat
Malta
Mauritius
Maldives
Malawi
Mexico
Malaysia
Mozambique
Namibia
New Caledonia
Niger
Norfolk Island
Nigeria
Nicaragua
Netherlands
Norway
Nepal
Nauru
Niue
New Zealand
Oman
Panama
Peru
French Polynesia
Papua New Guinea
Philippines
Pakistan
Poland
Saint Pierre and Miquelon
Pitcairn
Puerto Rico
Palestinian Territory, Occupied
Portugal
Palau
Paraguay
Qatar
Reunion
Romania
Russian Federation
Rwanda
Saudi Arabia
Solomon Islands
Seychelles
Sudan
Sweden
Singapore
Saint Helena
Slovenia
Svalbard and Jan Mayen
Slovakia
Sierra Leone
San Marino
Senegal
Somalia
Suriname
Sao Tome and Principe
El Salvador
Syrian Arab Republic
Swaziland
Turks and Caicos Islands
Chad
French Southern Territories
Togo
Thailand
Tajikistan
Tokelau
Timor-Leste
Turkmenistan
Tunisia
Tonga
Turkey
Trinidad and Tobago
Tuvalu
Taiwan, Province of China
Tanzania, United Republic of
Ukraine
Uganda
United States Minor Outlying Islands
United States
Uruguay
Uzbekistan
Holy See (Vatican City State)
Saint Vincent and the Grenadines
Venezuela
Virgin Islands, British
Virgin Islands, U.s.
Viet Nam
Vanuatu
Wallis and Futuna
Samoa
Yemen
Mayotte
South Africa
Zambia
Zimbabwe
Back
To the checkout
Reference number: