Measuring ranges
(adjustable in partial ranges):
0 ... 1000 °C
Sensor
thin-film thermopile
Spectral sensitivity
8 - 14 µm
Focussing range
0.15 ... 0.3m (close-up lens)
0.3m ... ∞ (standard lens)
Distance to target size
ratio
38 : 1 at 300 mm
(close-up lens)
40 : 1 at 300 mm
(standard lens)
Digital output
Periodic output of measure- ment data with adjustable
cycle time
Response time t90
≤ 100 ms
Resolution
≤ 0.5 K
(if smoothing is ≥ 30 ms)
Linearisation
digital via microcontroller
≥ 2000 adjustment Points
Measurement uncertainty
1 % of range and but at least
2 K (bei ε =1.0 and TA=23 °C)
Repeatability
1 K
Sighting device
through-the-lens sighting with target marking or laser target spot indicator
Ambient operating
temperature
0 ... 60 °C
Storage temperature
-20 ... 70 °C
Temperature coefficient with reference to 23 °C
≤ 0.1 K / K (at T < 200 °C)
≤ 0.05 %/K (at T > 200 °C)
of temperature reading
Data communication
PROFIBUS DP
Power supply requirements
22 - 27 V DC / ≤ 135 mA
(150 mA with switched on spotlight)
Ripple: ≤ 200 mV
Dimensions
Ø 65 x 200 mm
Housing material
Aluminium
Connection
screw terminal
Weight
approx. 0.8 kg
Protection
IP 65 according to DIN 40050
Adjustable parameters
Emissivity ε
10.0 bis 99.9 %
increment size 0.1 %
Smoothing function t98
0 - 16 sec
0.03 ... 4 sec. selfadaptive
Memory modes
- Min./Max. (peak picker)
- Double maximum with
adjustable hold time
Optional accessories
Calibration certificate
according to ISO 9001
Large variety of mounting
devices, digital displays,
software, etc.