Características:
- Gama: 300 a 1999 ° C
- Caixa de alumínio resistente (IP65)
- As teclas de função para ajustar os parâmetros, tais como emissividade
- Avistamento tubo para o alvo marcação (opcional)
- Interface serial Adaptix C para transferir os dados coletados para um PC
- Armazena até 64 amostras
DADOS TÉCNICOS
Pyrometer Portix H
Measuring ranges:
300 ... +1999 °C
Sensor:
Photo diode
Spectral range:
1.1 - 1.7 µm
Measurement area:
Ø 10 mm at 600 mm
Distance ratio:
60:1
Response time t90:
≤ 1 s
Display:
3½ LC-Display
Resolution:
0.1 K (< 200 °C)
1 K ( > 200 °C)
300 ... +1999 °C
Sensor:
Photo diode
Spectral range:
1.1 - 1.7 µm
Measurement area:
Ø 10 mm at 600 mm
Distance ratio:
60:1
Response time t90:
≤ 1 s
Display:
3½ LC-Display
Resolution:
0.1 K (< 200 °C)
1 K ( > 200 °C)
Measurement uncertainty:
4 K or 0.5 % of measured value
the higher value is valid
(< 1500 °C)
0.75 % of measured value
+ 1 Digit (< 1500 °C)
at ε = 1 and TA = 23 °C
Repeatability:
1 K
at ε = 1 and TA = 23 °C
Viewfinder:
Viewfinder with target marking for1 m, 2.5 m und ∞
(Typ PT 20/V AF1)
Ambient Temperature:
-10 ... +50 °C
Storage temperature:
-20 ... +60 °C
Temperature coefficient:
≤ 0.05 % / K
of measured value / K
deviation to TA = 23 °C
Power supply:
Batterie 9 V 6 LR 61
Dimensions:
(B x H x T)
175 x 60.5 x 35.5 mm
4 K or 0.5 % of measured value
the higher value is valid
(< 1500 °C)
0.75 % of measured value
+ 1 Digit (< 1500 °C)
at ε = 1 and TA = 23 °C
Repeatability:
1 K
at ε = 1 and TA = 23 °C
Viewfinder:
Viewfinder with target marking for1 m, 2.5 m und ∞
(Typ PT 20/V AF1)
Ambient Temperature:
-10 ... +50 °C
Storage temperature:
-20 ... +60 °C
Temperature coefficient:
≤ 0.05 % / K
of measured value / K
deviation to TA = 23 °C
Power supply:
Batterie 9 V 6 LR 61
Dimensions:
(B x H x T)
175 x 60.5 x 35.5 mm
Housing:
Aluminium
Weight:
Approx. 270 g incl. batterie
Protection:
IP 65 according to DIN 40050
Adjustable parameters:
Emissivity ε:
20 ... 100 %
Increments 0.1 %
Memory modes:
- Min.value
- Max.value
- Data memory for 64
temperature readings*
Standard accessories:
- Bag
Optionales Zubehör:
PC interface Adaptix for data transfer incl. driver Windows 95/98, Windows NT, XP
Calibration certificate according to ISO 9001
Emissivity changing sticker
Epsidot- sticker
9 V batterie
Aluminium
Weight:
Approx. 270 g incl. batterie
Protection:
IP 65 according to DIN 40050
Adjustable parameters:
Emissivity ε:
20 ... 100 %
Increments 0.1 %
Memory modes:
- Min.value
- Max.value
- Data memory for 64
temperature readings*
Standard accessories:
- Bag
Optionales Zubehör:
PC interface Adaptix for data transfer incl. driver Windows 95/98, Windows NT, XP
Calibration certificate according to ISO 9001
Emissivity changing sticker
Epsidot- sticker
9 V batterie