KELLER Home » ITS » Products » Stationary pyrometers » CellaTemp PA » CellaTemp PA 43
Target sightingMeasuring rangeLensFocus areaDistance ratio / Measuring field
Through-the-lensLaser spot lightVideo camera
600 - 1400 °CPZ 20.080.3 m - ∞30:1 / 150:1
650 - 1700 °CPZ 20.010.4 m - ∞45:1 / 230:1
PZ 20.030.2 - 0.4 m40:1 / 215:1
PZ 20.061.2 m - ∞75:1 / 371:1
PZ 20.050.2 m - ∞10:1 / 55:1
PZ 20.080.3 m - ∞30:1 / 150:1
PA 20.060.6 m - ∞95:1 / 500:1
750 - 2400 °CPZ 20.010.4 m - ∞50:1 / 350:1
PZ 20.030.2 - 0.4 m45:1 / 330:1
PZ 20.061.2 m - ∞85:1 / 580:1
PZ 20.050.2 m - ∞11:1 / 85:1
PZ 20.080.3 m - ∞34:1 / 230:1
PA 40.010.086-0.115 m0.89-1.57x0.22-0.29 mm
PA 20.060.6 m - ∞105:1 / 730:1
850 - 3000 °CPZ 20.010.4 m - ∞50:1 / 350:1
PZ 20.030.2 - 0.4 m45:1 / 330:1
PZ 20.061.2 m - ∞85:1 / 580:1
PZ 20.050.2 m - ∞11:1 / 85:1
PZ 20.080.3 m - ∞34:1 / 230:1
PA 40.010.086-0.115 m0.89-1.57x0.22-0.29 mm
PA 20.060.6 m - ∞105:1 / 730:1


  • Range of models
  • Field of View Calculator
  • Technical data
  • Mountings
  • Application
  • Request a quote
  • Downloads
  • Software
  • Accessories

Stationary Pyrometers

Panorama Pyrometer®
CellaTemp® PA 43

PA SeitenansichtPA DurchblickPA LaserPA KameraPA Objektive
The Panorama Pyrometer® CellaTemp® PA 43 with an innovative optical arrangement and no moving parts comes with a rectangular measurement area. The pyrometer works according to the two-colour measuring principle; therefore, the measurement area does not have to be filled completely by the hot target object. For example, a wire may move at random within the measurement area. Yet the pyrometer provides always a secure measurement reading within milliseconds. The target marker in the through-the-lens sighting device or, when using pyrometers with a video camera, the monitor in the control room, show the exact position and size of the rectangular measurement area.
Device:
Art.Nr.:
PGB-Nr.: ---
Mechanical accessories
Mountings
Electrical accessories
Optical accessories

Features:

  • Range: 600 to 3000 °C
  • Focusable, interchangeable optics with rectangular measurement area
  • Precision lenses with broadband antireflection coating
  • Short wavelength spectral response
  • LED display is easy to read from a distance
  • Test current can be applied to perform diagnostics
  • Signal processing: two analogue outputs and USB / RS485 interface.